Summary
generated automatically from NVD dataBudibase Server from 3.39.18 up to, but not including, 4.0.0 has a prototype pollution flaw in how it handles dynamic JSON keys in PUBLIC queries. An unauthenticated attacker can supply __proto__ as a key in a single request to the query execution endpoint, which reduces a MongoDB query filter to {}. This lets the attacker read, update, or delete every document in the collection. The flaw is rated CRITICAL with a CVSS v3.1 score of 10.0 and is classified as CWE-943.
NVD description
Budibase Server from 3.39.18 before 4.0.0 contains a prototype pollution vulnerability that allows unauthenticated attackers to erase MongoDB query filters by supplying __proto__ as a dynamic JSON key in PUBLIC queries. Attackers can send a single request to the query execution endpoint, reducing the filter to {} to read, update, or delete every document in the collection.
In-depth analysis on cveo.tech
This CVE is covered in an article: context, affected versions and published fixes.
CVSS v3.1 Score
Information
- Published
- 26 nov. 2026
- Updated
- 26 nov. 2026
- Status
- Received
- Source
- disclosure@vulncheck.com
Weaknesses (CWE)
Similar CVEs
Other vulnerabilities of type CWE-943
Know which CVEs hit the versions you run.
Add the product and its version: cveo.tech lists the CVEs that affect it right away, then alerts you by email when a new one affects it — including before NVD has finished its analysis. Free, an account is all it takes.